Victron Energy - Galvanic Isolator VDI-16, VDI-32 and VDI-64
The galvanic isolator prevents electrolytic corrosion. It blocks low
voltage DC currents that enter your boat via the shore power earth wire.
These currents can cause corrosion to the boat’s underwater metals,
like the hull, propeller, shaft and so on.
The galvanic isolator consists internally of two diodes which are
connected in anti-parallel fashion. When they are connected in this way,
the diodes allow current in both directions but only above a certain
threshold voltage. The voltage at which diodes conduct is about 1.4 Vdc.
The isolator is installed directly behind your boat's 230V
connection. The forward voltage from the galvanic isolator is higher
than the potential difference between metals. As a result, this voltage
will not allow conduction and as such, the galvanic isolator will
prevent any electrolytic current. However, if there is a (higher) error
voltage in the AC circuit, the diodes will allow current through and the
residual-current device will break the circuit.